Comparison of an Immunochromatographic Method for Rapid Identification of Group A Streptococcal Antigen With Culture Method
Thomas P. Ehrlich, MD;
Richard H. Schwartz, MD;
Raoul Wientzen, MD;
Mary Margaret Thorne, MT
Arch Fam Med. 1993;2(8):866-869.
Abstract
| |
Objectives To compare the sensitivity and specificity of Concise Strep A (Hybritech, San Diego, Calif), an immunochromatographic group A streptococcal rapid antigen detection system, with a two-plate culture method for the diagnosis of streptococcal pharyngitis, and to evaluate the need for routine back-up culture when this rapid test is used.
Design Throat cultures were obtained from 351 children with acute pharyngitis by duplicate rayon-tipped swabs held in parallel and vigorously rubbed against both tonsils and the posterior pharyngeal wall. One swab was tested for group A streptococcal antigen by a registered licensed laboratory technologist in the pediatrician's office. The other swab was streaked over each of two sheep blood agar plates, one of which was enhanced with trimethoprim in combination with sulfamethoxazole. The plain sheep blood agar plate was then incubated in a candle-extinguish jar. The enhanced agar plate was placed in a gas-pack anaerobic jar. Both plates were incubated for up to 48 hours at 35°C.
Setting A six-person group pediatric practice.
Participants Three hundred fifty-one children.
Results The Concise Strep A antigen detection test produced 129 positive results. Only six of the 129 were not confirmed by culture method. There were four false-negative rapid streptococcal antigen detection test results, all of which were found after a single overnight incubation. The sensitivity for the Concise Strep A test was 96.9% and the specificity was 97.4%. The plain 5% sheep blood agar plate (without trimethoprim and sulfamethoxazole), which was incubated in a candle-extinguish jar, identified 123 (97%) of the 127 positive throat cultures. The second 24-hour incubation and use of trimethoprim and sulfamethoxazole agar were not rewarding for this study.
Conclusions Concise Strep A, a polyclonal antibody test, in conjunction with a color immunochromatographic assay for soluble streptococcal carbohydrate antigen A appears to be accurate, sensitive, and specific when throat swabs are carefully obtained and when qualified, licensed laboratory technologists perform the procedure. Further studies should be done to confirm our findings, especially when nurses or office staff perform the rapid test procedure in the office setting. If our findings are confirmed, the use of back-up cultures for negative rapid test results obtained using Concise Strep A would be unnecessary.
Author Affiliations
From the Department of Family Practice, Medical College of Virginia, Fairfax Family Practice Center Inc (Dr Ehrlich); the Department of Pediatrics, Fairfax Hospital, Falls Church, Va (Dr Schwartz); the Department of Pediatrics, Georgetown University, Washington, DC (Dr Wientzen); and Vienna (Va) Pediatric Associates (Ms Thorne).
THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES
Rapid Diagnosis of Pharyngitis Caused by Group A Streptococci
Gerber and Shulman
Clin. Microbiol. Rev. 2004;17:571-580.
ABSTRACT
| FULL TEXT
Spectrum Bias of a Rapid Antigen Detection Test for Group A {beta}-Hemolytic Streptococcal Pharyngitis in a Pediatric Population
Hall et al.
Pediatrics 2004;114:182-186.
ABSTRACT
| FULL TEXT
Comparison of Throat Culture Methods for the Recovery of Group A Streptococci in a Pediatric Office Setting
Roddey et al.
JAMA 1995;274:1863-1865.
ABSTRACT
|